Article: TF140DU-135-V1000

Article: TF140DU-135-V1000
TF140DU-135-V1000 Thermal Overload Relay
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | TF140DU-135-V1000 |
Product ID: | 1SAZ431301R1003 |
EAN: | 4013614499531 |
Catalog Description: | TF140DU-135-V1000 Thermal Overload Relay |
Long Description: | TF140DU-135-V1000 Thermal Overload Relay with ATEX |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 2CDC106050M6802 |
Instructions and Manuals (Part 2): | 2CDC106082M6801 |
Dimension Diagram: | 1SAZ400404F0001 |
| |
Product Net Width: | 89 mm |
Product Net Height: | 140 mm |
Product Net Depth / Length: | 126 mm |
Product Net Weight: | 0.82 kg |
| |
Setting Range: | 100 ... 135 A |
Rated Operational Voltage: | Auxiliary Circuit 440 V DC |
Auxiliary Circuit 500 V AC | |
Main Circuit 690 V AC | |
Main Circuit 440 V DC | |
Rated Operational Current (Ie): | 135 A |
Rated Operational Current AC-3 (Ie): | 135 A |
Rated Frequency (f): | Auxiliary Circuit 50 Hz |
Auxiliary Circuit 60 Hz | |
Auxiliary Circuit DC | |
Main Circuit 60 Hz | |
Main Circuit 50 Hz | |
Main Circuit DC | |
Rated Impulse Withstand Voltage (Uimp): | Auxiliary Circuit 6 kV |
Main Circuit 8 kV | |
Rated Insulation Voltage (Ui): | 690 V |
Number of Poles: | 3 |
Number of Auxiliary Contacts NC: | 1 |
Number of Auxiliary Contacts NO: | 1 |
Number of Protected Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Auxiliary Circuit NC 10 A |
Auxiliary Circuit NO 6 A | |
Rated Operational Current AC-15 (Ie): | (120 V) NC 3 A |
(120 V) NO 1.5 A | |
(240 V) NC 3 A | |
(240 V) NO 1.5 A | |
(400 V) NC 1.9 A | |
(400 V) NO 1 A | |
(440 V) NC 1 A | |
(440 V) NO 1 A | |
(500 V) NC 1 A | |
(500 V) NO 1 A | |
Rated Operational Current DC-13 (Ie): | (125 V) NC 0.25 A |
(125 V) NO 0.25 A | |
(24 V) NC 1.25 A | |
(24 V) NO 1.25 A | |
(250 V) NC 0.12 A | |
(250 V) NO 0.04 A | |
(60 V) NC 0.25 A | |
(60 V) NO 0.25 A | |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP10 | |
Pollution Degree: | 3 |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible 1/2x 0.75 ... 2.5 mm² | |
Rigid 1/2x 0.75 ... 4 mm² | |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 16 ... 70 mm² |
Flexible with Insulated Ferrule 1/2x 16 ... 70 mm² | |
Flexible 1/2x 16 ... 70 mm² | |
Rigid 1/2x 16 ... 70 mm² | |
Tightening Torque: | Auxiliary Circuit 0.8 ... 1.2 N·m |
Main Circuit 8 ... 10 N·m | |
Wire Stripping Length: | Auxiliary Circuit 9 mm |
Main Circuit 25 mm | |
Recommended Screw Driver: | Auxiliary Circuit Pozidriv 2 |
Main Circuit Hexagon 4 | |
Suitable For: | AF116 |
AF140 | |
Standards: | IEC/EN 60947-1 |
IEC/EN 60947-4-1 | |
IEC/EN 60947-5-1 | |
UL 60947-1 | |
UL 60947-4-1 | |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 135 A |
Contact Rating UL/CSA: | (NC:) B600 |
(NO:) C300 | |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 6-2/0 AWG |
Stranded 1/2x 6-2/0 AWG | |
Connecting Capacity Auxiliary Circuit UL/CSA: | Flexible 1/2x 18-14 AWG |
Stranded 1/2x 18-14 AWG | |
Tightening Torque UL/CSA: | Auxiliary Circuit 12 in·lb |
| |
Ambient Air Temperature: | Operation -25 ... +55 °C |
Operation Compensated -25 ... +55 °C | |
Storage -40 ... +70 °C | |
Ambient Air Temperature Compensation: | Yes |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 12g |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
ABS Certificate: | 1SAA941004-0101 |
ATEX Certificate: | 1SAA941003-3901 |
BG Certificate: | 1SAA941012-2001 |
BV Certificate: | 1SAA941003-0201 |
CQC Certificate: | CQC2016010309922935 |
cUL Certificate: | cUL_E48139 |
Declaration of Conformity - CCC: | 2020980304001320 |
Declaration of Conformity - CE: | 1SAD938507-0192 |
DNV GL Certificate: | 1SAA941004-0301 |
EAC Certificate: | 1SAA941002-2702 |
Environmental Information: | 1SAC200090H0009 |
IECEx Certificate: | 1SAA941004-4001 |
Instructions and Manuals: | 2CDC106050M6802 |
Instructions and Manuals (Part 2): | 2CDC106082M6801 |
LR Certificate: | 1SAA941004-0501 |
RINA Certificate: | RINA_ELE098115XG |
RMRS Certificate: | 1SAA941002-0701 |
RoHS Information: | 1SAD938503-0192 |
UL Certificate: | UL_E48139 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 165 mm |
Package Level 1 Height: | 133 mm |
Package Level 1 Depth / Length: | 151 mm |
Package Level 1 Gross Weight: | 0.945 kg |
Package Level 1 EAN: | 4013614499531 |
Package Level 2 Units: | 4 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Gross Weight: | 8.786 kg |
Package Level 2 EAN: | 4013614503733 |
| |
ETIM 5: | EC000106 - Thermal overload relay |
ETIM 6: | EC000106 - Thermal overload relay |
ETIM 7: | EC000106 - Thermal overload relay |
eClass: | V11.0 : 27371501 |
UNSPSC: | 39121520 |
IDEA Granular Category Code (IGCC): | 5364 >> Overload relay |
Accessories |